GUOYUAN GY-FLC500M 500W Air-Cooled Pulsed Laser Cleaning Machine User Manual
GUOYUAN GY-FLC500M 500W Air-Cooled Pulsed Laser Cleaning Machine User Manual

GUOYUAN GY-FLC500M 500W Air-Cooled Pulsed Laser Cleaning Machine User Manual

Laser Insights China

Prezzo di listino $0.00 USD
Prezzo scontato $0.00 USD Prezzo di listino
Prezzo unitario per
In offerta

GUOYUAN GY-FLC500M 500W Air-Cooled Pulsed Laser Cleaning Machine User Manual PDF

  • Free English technical PDF guide for the GUOYUAN GY-FLC500M 500W air-cooled pulsed laser cleaning machine, covering laser safety, installation, touchscreen settings, 13 scan modes, process parameters, alarms, troubleshooting, maintenance, and after-sales service.

    This Laser Insights China edition organizes the GY-FLC500M manual into a practical reference for laser-cleaning operators, production teams, maintenance engineers, system integrators, and field service technicians. It explains the machine structure, operating environment, system startup and shutdown, parameter setup, cleaning-mode selection, process-library use, alarm monitoring, routine inspection, and safe professional maintenance.

    If you would like to purchase the physical product, you can click here.

    Good For

    • Safe Installation And Startup: Reviewing Class 4 laser precautions, protective eyewear, grounding, power requirements, cable inspection, cleaning-head checks, startup, enabling, operation, and shutdown.

    • Technical Specification Review: Confirming 500 W average laser power, 30-500 ns pulse width, 1-4000 kHz frequency range, 10 m fiber length, air cooling, single-phase 220 V power, and handheld or automatic operation.

    • Cleaning Process Setup: Configuring laser power, frequency, pulse width, scan speed, scan width, scan height, fill spacing, scan count, edge coefficient, damping delay, and field-lens correction.

    • 13 Scan Modes: Understanding linear, rectangular, rectangular II, circular, sinusoidal, spiral, free, ring, rotation, triangle, rotating-circle, rotating-line, and linear rotating-circle patterns.

    • Maintenance And Troubleshooting: Checking component alarms, laser signals, protective lenses, optical cleanliness, operating conditions, warranty limitations, and technical-support procedures.

    How To Download

    Add this GY-FLC500M manual to your cart and complete the free checkout. The English PDF will be delivered through our digital-download system.

    Note: This item is a downloadable PDF technical reference only. The GY-FLC500M laser cleaning machine, laser source, cleaning head, protective goggles, protective lenses, accessories, and related equipment are sold separately.

    Technical Download Details

    The GUOYUAN GY-FLC500M 500W Air-Cooled Pulsed Laser Cleaning Machine User Manual PDF focuses on safe operation, commissioning, process setup, alarm monitoring, maintenance, and service. It includes laser and electrical safety, product features and standards, operating-environment requirements, optical and mechanical specifications, cleaning-head and machine dimension diagrams, the equipment configuration list, step-by-step operation, touchscreen settings, 13 scan modes, a 100-set custom process database, the default process library, laser and scan parameters, activation guidance, alarm status, warranty limitations, and technical support.

    Use This File For

    • Operator Training: Learning the correct protective equipment, startup sequence, parameter-setting workflow, laser enabling procedure, cleaning operation, and shutdown sequence.

    • Machine Commissioning: Verifying the 220 V power supply, grounding, cleaning-head condition, system connections, language, distance measurement, temperature threshold, mirror settings, and field-lens coefficients.

    • Process Development: Selecting and refining scan patterns for rust, paint, oil, dirt, resin, coatings, plating layers, and oxide deposits on suitable substrates.

    • Production Setup: Using customizable parameter sets and the built-in process library to store, retrieve, and apply repeatable cleaning recipes.

    • Routine Service: Monitoring component alarms and laser signals, inspecting cables and protective optics, keeping the equipment clean, and arranging qualified technical service when required.

    Key Technical References

    • Laser output: Pulsed laser with at least 500 W average power, less than 5% power instability, 15 mJ maximum single-pulse energy, and 0-100% power adjustment.

    • Pulse parameters: 30-500 ns pulse length and 1-4000 kHz frequency range.

    • Scanning system: Dual-axis cleaning head with 13 scan modes and a continuously adjustable 0-300 mm scan range; 254 mm field lens standard, with 160, 330, and 420 mm options listed.

    • Machine specifications: Approximately 770 × 375 × 800 mm, about 69 kg, air-cooled, and suitable for handheld or automatic operation.

    • Operating environment: Single-phase 220 V ±10%, 50/60 Hz AC, total power consumption up to 3000 W, 0-40°C ambient temperature, and up to 80% humidity.

    Before Applying The Information

    Safety First: The GY-FLC500M contains a Class 4 high-power laser operating near 1064 nm or 1080 nm. Installation, commissioning, operation, and maintenance must be performed by trained personnel. Wear wavelength-appropriate certified laser-protection eyewear and protective clothing, provide reliable grounding and ventilation, control reflected and scattered radiation, keep optical interfaces clean, disconnect power before service, and never direct the cleaning head toward people or highly reflective surfaces.

    Digital Delivery

    This item is delivered as a digital technical reference. Complete checkout to receive the English PDF download link through the store delivery system.